WEKO3
アイテム
{"_buckets": {"deposit": "4694e49d-f0a9-4821-aac5-0dc1caede8a9"}, "_deposit": {"created_by": 17, "id": "10012", "owners": [17], "pid": {"revision_id": 0, "type": "depid", "value": "10012"}, "status": "published"}, "_oai": {"id": "oai:hsuh.repo.nii.ac.jp:00010012", "sets": ["591"]}, "author_link": ["32719", "32720", "32721", "32722", "32723"], "item_2_biblio_info_14": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-06", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "7", "bibliographicPageStart": "1", "bibliographicVolumeNumber": "26", "bibliographic_titles": [{"bibliographic_title": "北海道医療大学歯学雑誌", "bibliographic_titleLang": "ja"}]}]}, "item_2_creator_8": {"attribute_name": "著者名(英)", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "MUGURUMA, Takeshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "32719", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "IIJIMA, Masahiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "32720", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "YUASA, Toshihiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "32721", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "OKAYAMA, Miki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "32722", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "MIZOGUCHI, Itaru", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "32723", "nameIdentifierScheme": "WEKO"}]}]}, "item_2_description_1": {"attribute_name": "ページ属性", "attribute_value_mlt": [{"subitem_description": "P(論文)", "subitem_description_language": "ja", "subitem_description_type": "Other"}]}, "item_2_description_12": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "The aim of this study was to investigate the force delivery for a variety of types and sizes of commercially available nickel-titanium wires. The relationship of the magnitude of the force and the tooth displacement in a severe crowding case is discussed. Nine brands of nickel-titanium orthodontic wires in a variety of sizes were examined with a three-point bending test and a torsion test at 37℃. Most wires exhibited superelastic behavior for the three-point bending and torsion tests at 37℃. In the three-point bending test, the variation of the average load at 1.5mm deflection during unloading ranged from 0kgf for Copper Ni-Ti 40℃ with a 0.016×0.022 inch cross-section to 0.46kgf for ORTHO LINE with a 0.021×0.025 inch cross-section. The average torsion load at a rotation of 30°on deactivation varied from 0kgf-cm for Copper Ni-Ti 40℃ to 0.023kgf-cm for ORTHO LINE. The predicted torsional angles for the maxillary arch in the severe crowding case were smaller than expected and only three positions exceeded 20°. Considering the play between bracket slots and archwire, nickel-titanium orthodontic wires of the superelastic type may not exhibit superelastic properties for torsion in most clinical situations.", "subitem_description_language": "en", "subitem_description_type": "Other"}]}, "item_2_source_id_13": {"attribute_name": "雑誌書誌ID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12060694", "subitem_source_identifier_type": "NCID"}]}, "item_2_text_10": {"attribute_name": "著者所属(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "Department of Orthodontics, School of Dentistry, Health Sciences University of Hokkaido"}, {"subitem_text_language": "en", "subitem_text_value": "Department of Orthodontics, School of Dentistry, Health Sciences University of Hokkaido"}, {"subitem_text_language": "en", "subitem_text_value": "Department of Orthodontics, School of Dentistry, Health Sciences University of Hokkaido"}, {"subitem_text_language": "en", "subitem_text_value": "Department of Orthodontics, School of Dentistry, Health Sciences University of Hokkaido"}, {"subitem_text_language": "en", "subitem_text_value": "Department of Orthodontics, School of Dentistry, Health Sciences University of Hokkaido"}]}, "item_2_text_2": {"attribute_name": "記事種別(日)", "attribute_value_mlt": [{"subitem_text_language": "ja", "subitem_text_value": "原著"}]}, "item_2_text_3": {"attribute_name": "記事種別(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "ORIGINAL REPORT"}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2007-06-01"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "KJ00004763434.pdf", "filesize": [{"value": "1.8 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "mimetype": "application/pdf", "size": 1800000.0, "url": {"label": "Bending and torsional properties of commercial nickel-titanium orthodontic wires", "objectType": "fulltext", "url": "https://hsuh.repo.nii.ac.jp/record/10012/files/KJ00004763434.pdf"}, "version_id": "67df1178-6ffc-483a-a6cd-10ce68087658"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Nickel-titanium", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Orthodontic wire", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Bending", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Torsion", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Bending and torsional properties of commercial nickel-titanium orthodontic wires", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Bending and torsional properties of commercial nickel-titanium orthodontic wires", "subitem_title_language": "en"}]}, "item_type_id": "2", "owner": "17", "path": ["591"], "permalink_uri": "https://hsuh.repo.nii.ac.jp/records/10012", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2007-06-01"}, "publish_date": "2007-06-01", "publish_status": "0", "recid": "10012", "relation": {}, "relation_version_is_last": true, "title": ["Bending and torsional properties of commercial nickel-titanium orthodontic wires"], "weko_shared_id": -1}
Bending and torsional properties of commercial nickel-titanium orthodontic wires
https://hsuh.repo.nii.ac.jp/records/10012
https://hsuh.repo.nii.ac.jp/records/1001223d9cf45-605a-4e51-af99-8f55c5488959
名前 / ファイル | ライセンス | アクション |
---|---|---|
Bending and torsional properties of commercial nickel-titanium orthodontic wires (1.8 MB)
|
|
Item type | 紀要論文(ELS) / Departmental Bulletin Paper(ELS)(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-06-01 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Bending and torsional properties of commercial nickel-titanium orthodontic wires | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Nickel-titanium | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Orthodontic wire | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Bending | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Torsion | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ページ属性 | ||||||
内容記述タイプ | Other | |||||
内容記述 | P(論文) | |||||
言語 | ja | |||||
記事種別(日) | ||||||
ja | ||||||
原著 | ||||||
記事種別(英) | ||||||
en | ||||||
ORIGINAL REPORT | ||||||
著者名(英) |
MUGURUMA, Takeshi
× MUGURUMA, Takeshi× IIJIMA, Masahiro× YUASA, Toshihiro× OKAYAMA, Miki× MIZOGUCHI, Itaru |
|||||
著者所属(英) | ||||||
en | ||||||
Department of Orthodontics, School of Dentistry, Health Sciences University of Hokkaido | ||||||
著者所属(英) | ||||||
en | ||||||
Department of Orthodontics, School of Dentistry, Health Sciences University of Hokkaido | ||||||
著者所属(英) | ||||||
en | ||||||
Department of Orthodontics, School of Dentistry, Health Sciences University of Hokkaido | ||||||
著者所属(英) | ||||||
en | ||||||
Department of Orthodontics, School of Dentistry, Health Sciences University of Hokkaido | ||||||
著者所属(英) | ||||||
en | ||||||
Department of Orthodontics, School of Dentistry, Health Sciences University of Hokkaido | ||||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | The aim of this study was to investigate the force delivery for a variety of types and sizes of commercially available nickel-titanium wires. The relationship of the magnitude of the force and the tooth displacement in a severe crowding case is discussed. Nine brands of nickel-titanium orthodontic wires in a variety of sizes were examined with a three-point bending test and a torsion test at 37℃. Most wires exhibited superelastic behavior for the three-point bending and torsion tests at 37℃. In the three-point bending test, the variation of the average load at 1.5mm deflection during unloading ranged from 0kgf for Copper Ni-Ti 40℃ with a 0.016×0.022 inch cross-section to 0.46kgf for ORTHO LINE with a 0.021×0.025 inch cross-section. The average torsion load at a rotation of 30°on deactivation varied from 0kgf-cm for Copper Ni-Ti 40℃ to 0.023kgf-cm for ORTHO LINE. The predicted torsional angles for the maxillary arch in the severe crowding case were smaller than expected and only three positions exceeded 20°. Considering the play between bracket slots and archwire, nickel-titanium orthodontic wires of the superelastic type may not exhibit superelastic properties for torsion in most clinical situations. | |||||
言語 | en | |||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12060694 | |||||
書誌情報 |
ja : 北海道医療大学歯学雑誌 巻 26, 号 1, p. 1-7, 発行日 2007-06 |