<?xml version='1.0' encoding='UTF-8'?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-03-12T13:34:48Z</responseDate>
  <request verb="GetRecord" metadataPrefix="jpcoar_2.0" identifier="oai:hsuh.repo.nii.ac.jp:00006698">https://hsuh.repo.nii.ac.jp/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:hsuh.repo.nii.ac.jp:00006698</identifier>
        <datestamp>2023-12-21T06:41:03Z</datestamp>
        <setSpec>89:516</setSpec>
      </header>
      <metadata>
        <jpcoar:jpcoar xmlns:datacite="https://schema.datacite.org/meta/kernel-4/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcndl="http://ndl.go.jp/dcndl/terms/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:jpcoar="https://github.com/JPCOAR/schema/blob/master/2.0/" xmlns:oaire="http://namespace.openaire.eu/schema/oaire/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:rioxxterms="http://www.rioxx.net/schema/v2.0/rioxxterms/" xmlns:xs="http://www.w3.org/2001/XMLSchema" xmlns="https://github.com/JPCOAR/schema/blob/master/2.0/" xsi:schemaLocation="https://github.com/JPCOAR/schema/blob/master/2.0/jpcoar_scm.xsd">
          <dc:title xml:lang="ja">&lt;原著&gt;増感紙を併用したデンタルフィルムによる被曝線量低減化の試み</dc:title>
          <dc:title xml:lang="en">&lt;ORIGINAL ARTICLE&gt;Reduction of Exposure Dose from Dental Film Packs with Fluorecent Screen</dc:title>
          <dcterms:alternative>ja</dcterms:alternative>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="ja">輪島, 隆博</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="ja">田岡, 賢二</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="ja">池田, 博人</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="ja">武田, 忍</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="ja">金子, 昌幸</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="ja">高野, 英明</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="ja">佐藤, 祐子</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="ja">筧, 弘毅</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:subject xml:lang="en" subjectScheme="Other">Exposure dose</jpcoar:subject>
          <jpcoar:subject xml:lang="en" subjectScheme="Other">screen type</jpcoar:subject>
          <jpcoar:subject xml:lang="en" subjectScheme="Other">dental film</jpcoar:subject>
          <datacite:description xml:lang="ja" descriptionType="Other">P(論文)</datacite:description>
          <datacite:description descriptionType="Other">Dental film packs with fluorescent screens were made experimentally for the purpose of reducing the exposure dose and to conduct a quantitative analysis on the definition of radiographies taken with these materials. The type of screens were divided into (a) high resolutive type I, (b) high resolutive type II and (c) high sensitive type. The results obtained were as follows; (1) Compared with traditional dental films, the exposure dose could be decreased to 1/8.6 with high resolutive type I,1/14.9 with high resolutive type II and 1/55.8 with sensitive type. (2) In diagnosing, the definition with high resolutive type I and II were sufficeint in the case of routine examinations. The high sensitive type was inferior in resolution compared to high resolutive Type I and Type II. But this type was useful in the case of survaying without the necessity of high resolutive exposure, (3) Manufacturing costs of these materials are more expensive than the traditional ones, but should decrease in price when mass production can be carried out. (4) In the future, it will become necessary to stress the importance of decreasing the exposure dose since the image qualities are not improved to such a great extent.</datacite:description>
          <datacite:date dateType="Issued">1982-12-31</datacite:date>
          <dc:language>jpn</dc:language>
          <dc:type rdf:resource="http://purl.org/coar/resource_type/c_6501">departmental bulletin paper</dc:type>
          <jpcoar:identifier identifierType="URI">https://hsuh.repo.nii.ac.jp/records/6698</jpcoar:identifier>
          <jpcoar:sourceIdentifier identifierType="NCID">AN0008135X</jpcoar:sourceIdentifier>
          <jpcoar:sourceTitle xml:lang="ja">東日本歯学雑誌</jpcoar:sourceTitle>
          <jpcoar:volume>1</jpcoar:volume>
          <jpcoar:issue>1</jpcoar:issue>
          <jpcoar:pageStart>109</jpcoar:pageStart>
          <jpcoar:pageEnd>117</jpcoar:pageEnd>
          <jpcoar:file>
            <jpcoar:URI label="&lt;原著&gt;増感紙を併用したデンタルフィルムによる被曝線量低減化の試み" objectType="fulltext">https://hsuh.repo.nii.ac.jp/record/6698/files/KJ00000094309.pdf</jpcoar:URI>
            <jpcoar:mimeType>application/pdf</jpcoar:mimeType>
            <jpcoar:extent>2.1 MB</jpcoar:extent>
            <datacite:date dateType="Available">1982-12-31</datacite:date>
          </jpcoar:file>
        </jpcoar:jpcoar>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>
