{"created":"2023-05-15T11:32:18.852164+00:00","id":8715,"links":{},"metadata":{"_buckets":{"deposit":"1cfbb0e9-b5e2-42d5-8c97-ca66f3437403"},"_deposit":{"created_by":17,"id":"8715","owners":[17],"pid":{"revision_id":0,"type":"depid","value":"8715"},"status":"published"},"_oai":{"id":"oai:hsuh.repo.nii.ac.jp:00008715","sets":["89:570"]},"author_link":["26336","37303","37304","37305","37306"],"item_2_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002-06-30","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"73","bibliographicPageStart":"67","bibliographicVolumeNumber":"21","bibliographic_titles":[{"bibliographic_title":"東日本歯学雑誌","bibliographic_titleLang":"ja"}]}]},"item_2_creator_6":{"attribute_name":"著者名(日)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"大西, 隆","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"26336","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田中, 力延","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"37303","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐野, 友昭","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"37304","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"細川, 洋一郎","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"37305","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金子, 昌幸","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"37306","nameIdentifierScheme":"WEKO"}]}]},"item_2_description_1":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P(論文)","subitem_description_language":"ja","subitem_description_type":"Other"}]},"item_2_description_12":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"Purpose : This study evaluated the effectiveness of power Doppler ultrasonography by comparing power Doppler imaging to color Doppler imaging of the blood flow around the submandibular gland. Methods : Ultrasonographic examinations were performed with a SSD-1700 (Aloka Co., Japan) equipped with a linear electronic scanner using a 7.5MHz probe. Twenty-five healthy volunteers with no history of submandibular gland diseases were examined ultrasonographically. In the facial artery, the submental artery, the lingual artery, the palatine ascending artery, the suprahyoid branch of the lingual artery and the branch of the external carotid artery around the submandibular gland, ultrasonographic images obtained with power Doppler and color Doppler were compared. Results : The power Doppler was appeared more sensitive to demonstrate blood flow of the branch of the facial artery, the submental artery, the lingual artery, and the palatine ascending artery, which are inside and outside of the submandibular gland, but there was little difference in the sensitivity to blood flow in the main arteries. It was difficult to demonstrate blood flow of the suprahyoid branch of the lingual artery and the branch of the external carotid artery. Conclusion : The results showed that power Doppler imaging is more valuable to demonstrate blood flow around the submandibular gland.","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_2_source_id_13":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN0008135X","subitem_source_identifier_type":"NCID"}]},"item_2_text_10":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Department of Dental Radiology, School of Dentistry, Health Sciences University of Hokkaido"}]},"item_2_text_9":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_language":"ja","subitem_text_value":"北海道医療大学歯学部歯科放射線学講座"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2002-06-30"}],"displaytype":"detail","filename":"KJ00000095987.pdf","filesize":[{"value":"632.9 kB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"label":"<原著>顎下腺領域の血流における超音波ドプラ検査法の検討 : カラードプラ法とパワードプラ法の比較","objectType":"fulltext","url":"https://hsuh.repo.nii.ac.jp/record/8715/files/KJ00000095987.pdf"},"version_id":"9017d9bc-4545-4db0-9733-93a53c8eebc6"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"submandibular gland","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Doppler sonography","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"power Doppler imaging","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"color Doppler imaging","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"<原著>顎下腺領域の血流における超音波ドプラ検査法の検討 : カラードプラ法とパワードプラ法の比較","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"<原著>顎下腺領域の血流における超音波ドプラ検査法の検討 : カラードプラ法とパワードプラ法の比較","subitem_title_language":"ja"},{"subitem_title":"Evaluation of Doppler sonography of the blood flow in the submandibular gland : A comparison of power and color Doppler imaging","subitem_title_language":"en"}]},"item_type_id":"2","owner":"17","path":["570"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2002-06-30"},"publish_date":"2002-06-30","publish_status":"0","recid":"8715","relation_version_is_last":true,"title":["<原著>顎下腺領域の血流における超音波ドプラ検査法の検討 : カラードプラ法とパワードプラ法の比較"],"weko_creator_id":"17","weko_shared_id":-1},"updated":"2024-02-27T23:59:34.263196+00:00"}