WEKO3
アイテム
Validity and reliability of a wearable photoplethysmographic sensor as an indicator of autonomic nervous system activity in psychophysiological studies
https://hsuh.repo.nii.ac.jp/records/2000357
https://hsuh.repo.nii.ac.jp/records/20003571225eafb-1f5a-4670-bf62-464184538390
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2024-08-22 | |||||||||||
タイトル | ||||||||||||
タイトル | Validity and reliability of a wearable photoplethysmographic sensor as an indicator of autonomic nervous system activity in psychophysiological studies | |||||||||||
言語 | en | |||||||||||
言語 | ||||||||||||
言語 | eng | |||||||||||
著者 |
Tomomi, Hamabata
× Tomomi, Hamabata
× Naomi, Dodo
× Ryusaku, Hashimoto
|
|||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | autonomic nervous system (ANS) | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | photoplethysmography (PPG) | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | electrocardiography(ECG) | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | cold pressor test (CPT) | |||||||||||
資源タイプ | ||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||
資源タイプ | departmental bulletin paper | |||||||||||
アクセス権 | ||||||||||||
アクセス権 | open access | |||||||||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||||||||
抄録 | ||||||||||||
内容記述タイプ | Abstract | |||||||||||
内容記述 | Background: Several studies have reported on using photoplethysmography (PPG) waveform data as a pulse wave, using mobile monitoring with wearable photoplethysmographic sensors. Objectives: This study puported to verify whether PPG waveform data during the cold pressor test (CPT), measured, through mobile monitoring, with a wearable photoplethysmographic sensor (Polar Verity Sense, Polar Electro Oy, Kempele, Finland) were reliable and valid indicators of the autonomic nervous system. Methods: Electrocardiography (ECG) and photoplethysmography (PPG) waveform data during the CPT were compared in 30 healthy participants. ECG waveform data were obtained in the lead II. The PPG waveform data were measured using the Polar Verity Sense on the arm. We used the Bland-Altman test and the Intraclass correlation coefficient (ICC) to examine the ECG and PPG waveform data consistency. This experiment consisted of three phases: Resting phase (Rest), Cold presser test (CPT), and Recovery phase (Recovery). Results: The respective indices of the ECG and PPG data showed similar changes during Rest, CPT, and Recovery. The Cardiac Vagal and Sympathetic Indices (CVI/CSI), calculated by Lorenz plot analysis, showed no proportional errors but significant fixed errors. The consistency between CVI and CSI was also imperfect. Conclusion: During CPT, each indicator on the PPG waveform data exhibited the same pattern as the results of each indicator on the ECG waveform data. CVI and CSI values calculated on PPG data from Polar Verity Sense showed fixed errors compared to the gold standard index ECG data, but no proportional errors. We considered that the CVI and CSI values calculated on PPG data from Polar Verity Sense showed consistency with those values of ECG. |
|||||||||||
言語 | en | |||||||||||
書誌情報 |
ja : 北海道医療大学心理科学部研究紀要 en : Journal of Psychological Science Health Sciences University of Hokkaido 号 18・19, p. 15-20, 発行日 2024-03-31 |
|||||||||||
ISSN | ||||||||||||
収録物識別子タイプ | ISSN | |||||||||||
収録物識別子 | 18809804 | |||||||||||
出版タイプ | ||||||||||||
出版タイプ | VoR | |||||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |