WEKO3
アイテム
<原著>増感紙を併用したデンタルフィルムによる被曝線量低減化の試み
https://hsuh.repo.nii.ac.jp/records/6698
https://hsuh.repo.nii.ac.jp/records/6698ec8d97f8-f41b-4790-a1f4-6597c1adebc5
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文(ELS) / Departmental Bulletin Paper(ELS)(1) | |||||
---|---|---|---|---|---|---|
公開日 | 1982-12-31 | |||||
タイトル | ||||||
タイトル | <原著>増感紙を併用したデンタルフィルムによる被曝線量低減化の試み | |||||
言語 | ja | |||||
タイトル | ||||||
タイトル | <ORIGINAL ARTICLE>Reduction of Exposure Dose from Dental Film Packs with Fluorecent Screen | |||||
言語 | en | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Exposure dose | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | screen type | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | dental film | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ページ属性 | ||||||
内容記述タイプ | Other | |||||
内容記述 | P(論文) | |||||
言語 | ja | |||||
著者名(日) |
輪島, 隆博
× 輪島, 隆博× 田岡, 賢二× 池田, 博人× 武田, 忍× 金子, 昌幸× 高野, 英明× 佐藤, 祐子× 筧, 弘毅 |
|||||
著者所属(日) | ||||||
ja | ||||||
東日本学園大学歯学部附属病院放射線部/東日本学園大学歯学部歯科放射線学講座 | ||||||
著者所属(英) | ||||||
en | ||||||
Division of Radiology, Dental Hospital HIGASHI-NIPPON-GAKUEN UNIVERSITY/Department of Dental Radiology, School of Dentist HIGASHI-NIPPON-GAKUEN UNIVERSITY | ||||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Dental film packs with fluorescent screens were made experimentally for the purpose of reducing the exposure dose and to conduct a quantitative analysis on the definition of radiographies taken with these materials. The type of screens were divided into (a) high resolutive type I, (b) high resolutive type II and (c) high sensitive type. The results obtained were as follows; (1) Compared with traditional dental films, the exposure dose could be decreased to 1/8.6 with high resolutive type I,1/14.9 with high resolutive type II and 1/55.8 with sensitive type. (2) In diagnosing, the definition with high resolutive type I and II were sufficeint in the case of routine examinations. The high sensitive type was inferior in resolution compared to high resolutive Type I and Type II. But this type was useful in the case of survaying without the necessity of high resolutive exposure, (3) Manufacturing costs of these materials are more expensive than the traditional ones, but should decrease in price when mass production can be carried out. (4) In the future, it will become necessary to stress the importance of decreasing the exposure dose since the image qualities are not improved to such a great extent. | |||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN0008135X | |||||
書誌情報 |
ja : 東日本歯学雑誌 巻 1, 号 1, p. 109-117, 発行日 1982-12-31 |
|||||
出版タイプ | ||||||
出版タイプ | VoR |