WEKO3
アイテム
<原著>濃度の異なる溶液間の電橋にろ紙を用いたときに発生する電位差
https://hsuh.repo.nii.ac.jp/records/8065
https://hsuh.repo.nii.ac.jp/records/8065ffa41506-9d39-43fa-9230-94fe8190a346
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文(ELS) / Departmental Bulletin Paper(ELS)(1) | |||||
---|---|---|---|---|---|---|
公開日 | 1995-06-30 | |||||
タイトル | ||||||
タイトル | <原著>濃度の異なる溶液間の電橋にろ紙を用いたときに発生する電位差 | |||||
言語 | ja | |||||
タイトル | ||||||
タイトル | <ORGINAL ARTICLE>The potential differences between two solutions with different concentrations of electrolytes using filter paper as a bridge. | |||||
言語 | en | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Potential between two fluids | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Filter paper bridge | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Bias voltage | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Resting saliva | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Stimulated saliva | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ページ属性 | ||||||
内容記述タイプ | Other | |||||
内容記述 | P(論文) | |||||
言語 | ja | |||||
著者名(日) |
猪股, 孝四郎
× 猪股, 孝四郎× 鈴木, 光代× 星, 和明× 太田, 勲× 倉橋, 昌司 |
|||||
著者所属(日) | ||||||
ja | ||||||
北海道医療大学歯学部/北海道医療大学看護福祉学部 | ||||||
著者所属(英) | ||||||
en | ||||||
Department of Oral Physiology, School of Dentistry/Department of Medical Science, School of Nursing & Social Services, HEALTH SCIENCE UNIVERSITY OF HOKKAIDO | ||||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | This study investigated how the magnitude of potential differences between two solutions containing different concentrations of electrolytes is affected by the type of filter paper used as bridge between the two solutions The following results were obtained. (1) Potential differences were obtained with filter paper as the bridge between two solutions with different concentrations of electrolyte. The potential difference was comparable to the bias voltage in the circuit. The mechanism of generation of the potential difference was attributed to the concentration cell. It is suggested that filter paper acts as a semipermeable membrane similar to the living cell membrane or an ion electrode membrane. (2) There was no significant potential difference with agar drum (dissolved with saline) as the bridge. This result appears to be a result of an absence of ion transfer with in the agar drum. (3) The magnitude of the potential difference varied with the type of filter paper used for the bridge. Variations in the magnitude may be attributed to differences in ionic transfer in filter paper. (4) There were potential differences between resting and stimulated saliva, and between saliva and physiological saline. It is considered that fluids such as resting and stimulated saliva, and physiological saline act as electrical generators. | |||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN0008135X | |||||
書誌情報 |
ja : 東日本歯学雑誌 巻 14, 号 1, p. 71-76, 発行日 1995-06-30 |
|||||
出版タイプ | ||||||
出版タイプResource | VoR |