Item type |
紀要論文(ELS) / Departmental Bulletin Paper(ELS)(1) |
公開日 |
2004-12-31 |
タイトル |
|
|
タイトル |
Development of a safe and quick method for removal of intermaxillary fixation with superelastic Ni-Ti wire |
|
言語 |
en |
言語 |
|
|
言語 |
eng |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Intermaxillary fixation release |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Ni-Ti alloy wire |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Dental anesthesia |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Oral and orthognathic surgery |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Emergency in dentistry |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
departmental bulletin paper |
ページ属性 |
|
|
内容記述タイプ |
Other |
|
内容記述 |
P(論文) |
|
言語 |
ja |
記事種別(日) |
|
|
|
ja |
|
|
原著 |
記事種別(英) |
|
|
|
en |
|
|
ORIDINAL REPORT |
著者名(日) |
Masaru, KUDO
Takuro, KAWAI
Atsue, YAMAZAKI
Shigeru, UGA
Hanako, OHKE
Masahiro, KOKUBU
Itaru, MIZOGUCHI
Noboru, SHINYA
|
著者名(英) |
KUDO, Masaru
KAWAI, Takuro
YAMAZAKI, Atsue
UGA, Shigeru
OHKE, Hanako
KOKUBU, Masahiro
MIZOGUCHI, Itaru
SHINYA, Noboru
|
著者所属(英) |
|
|
|
en |
|
|
Department of Dental Anesthesiology, School of Dentistry, Health Sciences University of Hokkaido |
著者所属(英) |
|
|
|
en |
|
|
Department of Dental Anesthesiology, School of Dentistry, Health Sciences University of Hokkaido |
著者所属(英) |
|
|
|
en |
|
|
Department of Orthodontics, School of Dentistry, Health Sciences University of Hokkaido |
著者所属(英) |
|
|
|
en |
|
|
Department of Orthodontics, School of Dentistry, Health Sciences University of Hokkaido |
著者所属(英) |
|
|
|
en |
|
|
Department of Dental Anesthesiology, School of Dentistry, Health Sciences University of Hokkaido |
著者所属(英) |
|
|
|
en |
|
|
Department of Dental Anesthesiology, School of Dentistry, Health Sciences University of Hokkaido |
著者所属(英) |
|
|
|
en |
|
|
Department of Orthodontics, School of Dentistry, Health Sciences University of Hokkaido |
著者所属(英) |
|
|
|
en |
|
|
Department of Dental Anesthesiology, School of Dentistry, Health Sciences University of Hokkaido |
抄録(英) |
|
|
内容記述タイプ |
Other |
|
内容記述 |
To improve emergency intermaxillary fixation release, a novel method of intermaxillary fixation, in which super-elastic nickel-titan (Ni-Ti) alloy wires were applied at 2 places (Method A) was developed. Method A was compared to the previous method (Method B : fixing the jaw at 3 places with stainless steel wires), in terms of the time required to remove the wires and the number of pieces of cut wire left in the oral cavity and pharynx. The average time for removing the wires was 14.5 ± 9.9 (mean ± SD) seconds for Method A, and 79.1 ± 53.1 seconds for Method B. The average time was significantly shorter in Method A than in Method B (p < 0.01). The number of pieces of cut wire left was zero with Method A. These findings suggest that the novel method (Method A) provides quick and safe wire removal and improves the safety and quality of dentistry in emergency cases. |
|
言語 |
en |
雑誌書誌ID |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AN0008135X |
書誌情報 |
ja : 東日本歯学雑誌
巻 23,
号 2,
p. 175-181,
発行日 2004-12-31
|
出版タイプ |
|
|
出版タイプ |
VoR |