A study on nasotracheal intubation to prevent injury to the nasopharyngeal mucous membrane : Comparison of the bougie method and the gastric tube guide method
https://hsuh.repo.nii.ac.jp/records/9922
https://hsuh.repo.nii.ac.jp/records/992200072563-3784-4362-91c6-f575413ab593
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文(ELS) / Departmental Bulletin Paper(ELS)(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2005-06-30 | |||||
タイトル | ||||||
タイトル | A study on nasotracheal intubation to prevent injury to the nasopharyngeal mucous membrane : Comparison of the bougie method and the gastric tube guide method | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Nasotracheal intubation | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Safe propulsion | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Nasogastric tubes as guie intubation (NTGI) | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Bougie inferior nasal meatus asn nasotracheal intubation (BINI) | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ページ属性 | ||||||
内容記述タイプ | Other | |||||
内容記述 | P(論文) | |||||
言語 | ja | |||||
記事種別(日) | ||||||
ja | ||||||
症例報告 | ||||||
記事種別(英) | ||||||
en | ||||||
CLINICAL report | ||||||
著者名(英) |
KUDO, Masaru
× KUDO, Masaru× SHINYA, Noboru |
|||||
著者所属(英) | ||||||
en | ||||||
Department of Dental Anesthesiology, School of Dentistry, Health sciences University of Hokkaido | ||||||
著者所属(英) | ||||||
en | ||||||
Department of Dental Anesthesiology, School of Dentistry, Health sciences University of Hokkaido | ||||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Nasotracheal intubation with general anesthesia is performed for dental treatment and oral surgery. However, nasotracheal intubation causes nasal bleeding and injury to the mucous membrane of the nasopharynx. This report describes the introduction of Nasogastric tubes with the guide intubation (NTGI) method and discusses its usefulness, and further reports a comparison of the clinical usefulness of the NTGI method (our novel method) and the bougie inferior nasal meatus (BINI) method. The NTGI was performed clinically and the results of 30cases were confirmed by fiberscopy, showing no cases of injury. The proportion of cases with bleeding from the inferior nasal meatus was similar in the NTGI and bougie inferior nasal meatus as nasotracheal intubation (BINI) methods. The NTGI method prevented injury to the pharyngeal mucous membrane at the time of nasotracheal intubation. Therefore, the results indicated that the NTGI method is safe for nasotracheal intubation. In the present study, the intubation tube was changed to prevent pharyngeal injury. The tube tip was made of a soft material (soft PVC ; polyvinyl chloride) and with an obtuse angle, and the tube shape was changed. Although the intubation procedures were safe because the intubation tube material was soft, there is the possibility of obstruction of the nasal cavity during general anesthesia. Further studies are required to develop tubes for safer tracheal intubation during general anesthesia and when regaining consciousness as well as during intubation. | |||||
言語 | en | |||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12060694 | |||||
書誌情報 |
ja : 北海道医療大学歯学雑誌 巻 24, 号 1, p. 71-75, 発行日 2005-06-30 |