{"_buckets": {"deposit": "48f7780d-d6bb-40d5-ac11-8f674bad16bf"}, "_deposit": {"created_by": 17, "id": "7127", "owners": [17], "pid": {"revision_id": 0, "type": "depid", "value": "7127"}, "status": "published"}, "_oai": {"id": "oai:hsuh.repo.nii.ac.jp:00007127", "sets": ["534"]}, "author_link": ["21703", "34758", "34759", "34760", "34761"], "item_1693191265938": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_type": "VoR"}]}, "item_2_biblio_info_14": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1984-06-30", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "26", "bibliographicPageStart": "21", "bibliographicVolumeNumber": "3", "bibliographic_titles": [{"bibliographic_title": "東日本歯学雑誌", "bibliographic_titleLang": "ja"}]}]}, "item_2_creator_6": {"attribute_name": "著者名(日)", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "猪股, 孝四郎", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "21703", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高桑, 光代", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "34758", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "玉川, 恭子", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "34759", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "倉橋, 昌司", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "34760", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中村, 治雄", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "34761", "nameIdentifierScheme": "WEKO"}]}]}, "item_2_description_1": {"attribute_name": "ページ属性", "attribute_value_mlt": [{"subitem_description": "P(論文)", "subitem_description_language": "ja", "subitem_description_type": "Other"}]}, "item_2_description_12": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "It is well known that when the tongue is stimulated, secretory potentials are recorded in the human parotid. When these potentials are continuously recorded, the time-course of these secretory potentials would be clarified. In this experiment, the individual time-course of secretory potentials sometimes differed among each other. The results obtained are summarized as follows. 1) At times the time-course of secretory potentials in one subject did not show the same patterns in spite of the similar salivation volume (2.5-3.0ml). 2) The deflection in secretory potential recorded on the suction capsule is about -10 mV, while the deflection recorded on the mucous membrane at about 10 mm distant from papilla parotidea and on the skin over parotid gland are -0.3 mV. The difference in secretory potentials due to the different position of recording electrodes is great. 3) The time-course of secretory potentials showed different patterns due to the different psychological conditions of subject (hunger, irritation etc. ). 4) The negative deflection in secretory potentials were seen in 4 subjects, while the positive deflection was seen in one subject.", "subitem_description_type": "Other"}]}, "item_2_source_id_13": {"attribute_name": "雑誌書誌ID", "attribute_value_mlt": [{"subitem_source_identifier": "AN0008135X", "subitem_source_identifier_type": "NCID"}]}, "item_2_text_10": {"attribute_name": "著者所属(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "Department of Oral Physiology, School of Dentistry, HIGASHI-NIPPON-GAKUEN UNIVERSITY"}]}, "item_2_text_9": {"attribute_name": "著者所属(日)", "attribute_value_mlt": [{"subitem_text_language": "ja", "subitem_text_value": "東日本学園大学歯学部口腔生理学講座"}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "1984-06-30"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "KJ00000094394.pdf", "filesize": [{"value": "388.4 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "mimetype": "application/pdf", "size": 388400.0, "url": {"label": "\u003c原著\u003e耳下腺唾液分泌と電位変動について : II.ヒト耳下腺の分泌電位経過における疑問点", "objectType": "fulltext", "url": "https://hsuh.repo.nii.ac.jp/record/7127/files/KJ00000094394.pdf"}, "version_id": "ce2a076e-0ed8-453a-aa22-389ae13f122b"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Sour stimulation", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "parotid secretory potential", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "psychologycal condition", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "\u003c原著\u003e耳下腺唾液分泌と電位変動について : II.ヒト耳下腺の分泌電位経過における疑問点", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "\u003c原著\u003e耳下腺唾液分泌と電位変動について : II.ヒト耳下腺の分泌電位経過における疑問点", "subitem_title_language": "ja"}, {"subitem_title": "\u003cORIGINAL ARTICLE\u003eA Study on the Parotid Salivation and the Changes in Electrical Potential : II. Some Problems in the Time-Course of Secretory Potentials in Human Parotid", "subitem_title_language": "en"}]}, "item_type_id": "2", "owner": "17", "path": ["534"], "permalink_uri": "https://hsuh.repo.nii.ac.jp/records/7127", "pubdate": {"attribute_name": "PubDate", "attribute_value": "1984-06-30"}, "publish_date": "1984-06-30", "publish_status": "0", "recid": "7127", "relation": {}, "relation_version_is_last": true, "title": ["\u003c原著\u003e耳下腺唾液分泌と電位変動について : II.ヒト耳下腺の分泌電位経過における疑問点"], "weko_shared_id": -1}
<原著>耳下腺唾液分泌と電位変動について : II.ヒト耳下腺の分泌電位経過における疑問点
https://hsuh.repo.nii.ac.jp/records/7127
https://hsuh.repo.nii.ac.jp/records/71272c49fbc0-3bf9-43c7-b434-9fe03c54c7c3
名前 / ファイル | ライセンス | アクション |
---|---|---|
<原著>耳下腺唾液分泌と電位変動について : II.ヒト耳下腺の分泌電位経過における疑問点 (388.4 kB)
|
|
Item type | 紀要論文(ELS) / Departmental Bulletin Paper(ELS)(1) | |||||
---|---|---|---|---|---|---|
公開日 | 1984-06-30 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | <原著>耳下腺唾液分泌と電位変動について : II.ヒト耳下腺の分泌電位経過における疑問点 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | <ORIGINAL ARTICLE>A Study on the Parotid Salivation and the Changes in Electrical Potential : II. Some Problems in the Time-Course of Secretory Potentials in Human Parotid | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Sour stimulation | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | parotid secretory potential | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | psychologycal condition | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ページ属性 | ||||||
内容記述タイプ | Other | |||||
内容記述 | P(論文) | |||||
言語 | ja | |||||
著者名(日) |
猪股, 孝四郎
× 猪股, 孝四郎× 高桑, 光代× 玉川, 恭子× 倉橋, 昌司× 中村, 治雄 |
|||||
著者所属(日) | ||||||
ja | ||||||
東日本学園大学歯学部口腔生理学講座 | ||||||
著者所属(英) | ||||||
en | ||||||
Department of Oral Physiology, School of Dentistry, HIGASHI-NIPPON-GAKUEN UNIVERSITY | ||||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | It is well known that when the tongue is stimulated, secretory potentials are recorded in the human parotid. When these potentials are continuously recorded, the time-course of these secretory potentials would be clarified. In this experiment, the individual time-course of secretory potentials sometimes differed among each other. The results obtained are summarized as follows. 1) At times the time-course of secretory potentials in one subject did not show the same patterns in spite of the similar salivation volume (2.5-3.0ml). 2) The deflection in secretory potential recorded on the suction capsule is about -10 mV, while the deflection recorded on the mucous membrane at about 10 mm distant from papilla parotidea and on the skin over parotid gland are -0.3 mV. The difference in secretory potentials due to the different position of recording electrodes is great. 3) The time-course of secretory potentials showed different patterns due to the different psychological conditions of subject (hunger, irritation etc. ). 4) The negative deflection in secretory potentials were seen in 4 subjects, while the positive deflection was seen in one subject. | |||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN0008135X | |||||
書誌情報 |
ja : 東日本歯学雑誌 巻 3, 号 1, p. 21-26, 発行日 1984-06-30 |
|||||
出版タイプ | ||||||
出版タイプ | VoR |