WEKO3
アイテム
小型動物における骨シンチグラフィーの検討
https://hsuh.repo.nii.ac.jp/records/7242
https://hsuh.repo.nii.ac.jp/records/7242d3a83215-4aaf-4ae3-9592-61742de6d3eb
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文(ELS) / Departmental Bulletin Paper(ELS)(1) | |||||
---|---|---|---|---|---|---|
公開日 | 1986-06-01 | |||||
タイトル | ||||||
タイトル | 小型動物における骨シンチグラフィーの検討 | |||||
言語 | ja | |||||
タイトル | ||||||
タイトル | Evaluation of Bone Scintigraphy in the Small Animals | |||||
言語 | en | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Bone scintigraphy | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | pinhole collimeter | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | gamma camera | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | rat skeleton | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | mouse skeleton | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ページ属性 | ||||||
内容記述タイプ | Other | |||||
内容記述 | P(論文) | |||||
言語 | ja | |||||
記事種別(日) | ||||||
原著 | ||||||
記事種別(英) | ||||||
en | ||||||
ORIGINAL ARTICLE | ||||||
著者名(日) |
金子, 昌幸
× 金子, 昌幸× 小林, 光道× 江埼, 一郎× 竹林, 義人× 金子, 和子 |
|||||
著者所属(日) | ||||||
ja | ||||||
東日本学園大学歯学部歯科放射線学講座 | ||||||
著者所属(英) | ||||||
en | ||||||
epartment of Dental Radiology, School of Dentistry, HIGASHI-NIPPON-GAKUEN UNIVERSITY | ||||||
著者所属(英) | ||||||
en | ||||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Bone scintigraphy was attempted in the rat and mouse skeleton using a human gamma camera with a pinhole collimeter improved in 1986 by Kaneko and his co-workers. Then, the bone scan images obtained were evaluated whether they could be applied or not to experimental studies in the small animals. The spot scan scintigrams obtained from the rat thorax were sufficiently clear to detect and observe the bone structure in the rat skeleton, but those obtained from the mouse thorax were not sufficiently clear as compared with the scintigrams of the rat. Whole body scan images obtained from the rat and mouse skeleton had the same resolution obtained in 1979 by Nagata and his co-workers. All of these results showed that bone scintigraphy in the small animals were useful in examining experimentally occured bone diseases using the rat and mouse. | |||||
言語 | en | |||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN0008135X | |||||
書誌情報 |
ja : 東日本歯学雑誌 巻 5, 号 1, p. 51-57, 発行日 1986-06 |
|||||
出版タイプ | ||||||
出版タイプ | VoR |